RKI Instruments Explosion Proof Pneumatic Sample Draw Module 81-SDME2-09-P2 serves as a precision thermal calibration unit for International Standards in hazardous area gas extraction and Class I, Division 1 explosion-proof audits.
- Operating Range: 0.5 to 1.0 SCFH Adjustable Flow.
- Accuracy Standard: Pneumatic Aspirator Sampling Precision.
- Certified Compliance: Class I, Division 1, Groups B, C, & D.
- Data Logging: 1-Year Manufacturer Warranty Records.
- Process Connection: Wall Mount or Pipe Stand Bracket Interface.
RKI Instruments Sample Drawing Module Aspirator Rotameter 81-SDME2-03 acts as a secondary standard PRT probe for North American Standards in electrochemical sensor sampling and reliable venturi-effect audits for standard flow aspirator modules.
- Operating Range: Standard Flow Aspirator Adapter.
- Accuracy Standard: High Built-in Rotameter Verification.
- Certified Compliance: NEMA 4X / Explosion Proof Standard.
- Data Logging: Visual Flow Verification Records.
- Process Connection: 1/4" Compression Fitting Interface.
RKI Instruments Fixed Chlorine Cl2 Gas Detector 65-2484RK-34 acts as a secondary standard PRT probe for North American Standards in water treatment plant monitoring and toxic Cl2 electrochemical cell audits.
- Operating Range: 0 to 3.0 ppm Detection Range.
- Accuracy Standard: T90 < 30 Seconds Response Precision.
- Certified Compliance: Class I, Division 1, Groups B, C, & D.
- Data Logging: 4-20 mA (3-wire) Output Signal Records.
- Process Connection: Cast Aluminum Junction Box Interface.
GE Panametrics OXY-IQ Oxygen Analyzer (2-Wire/IS) is a loop-powered transmitter designed for oxygen measurement in nitrogen blanketing and glove boxes, offering a user-selectable range and an integral LCD with a tactile keypad interface.
- Measurement Range: 0-10,000 ppm up to 0-25% O2.
- Sensor Technology: Galvanic Fuel Cell (Electrochemical).
- Safety Rating: Intrinsically Safe (with barriers).
- Inlet Pressure: Up to 1.3 bar (Standard).
- Display: Integral LCD with keypad.
RKI Instruments Methane Tanker-Dock Alum 34L 721-001-TT delivers a secondary standard PRT probe for International Standards in marine and logistics fleets and automated 50% LEL methane testing for Tanker/Transport docking stations.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High 500 psig Pressure Rating.
- Certified Compliance: TT-Series Marine Docking Standard.
- Data Logging: 48 Month Non-Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
RKI Instruments 3-Gas Mix H2S/CO/CH4 TT-Series Alum 34L 72-5301RK-TT functions as a secondary standard PRT probe for North American Standards in oxygen-free marine mixtures and automated testing system audits.
- Operating Range: 34 Liters High Pressure Volume.
- Accuracy Standard: High ±2% Analytical Accuracy.
- Certified Compliance: NIST Traceable Reference Standard.
- Data Logging: 24 Month Reactive Gas Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
RKI Instruments Isobutane 10% LEL Sensitive-Leak Alum 34L 722-102-10 serves as a precision thermal calibration unit for International Standards in low-range isobutane reference and sensitive alarm point verification audits.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High ±2% Analytical Accuracy.
- Certified Compliance: NIST Traceable Reference Standard.
- Data Logging: 48 Month Non-Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
RKI Instruments Isobutane 20% LEL Multi-Point Alum 34L 722-102-20 acts as a secondary standard PRT probe for North American Standards in combustible gas sensors and partial-scale isobutane calibration audits for multi-point linearity testing.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High ±2% Analytical Accuracy.
- Certified Compliance: NIST Traceable Reference Standard.
- Data Logging: 48 Month Non-Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
RKI Instruments Isobutane 30% LEL Intermediate Alum 34L 722-102-30 serves as a precision thermal calibration unit for International Standards in industrial process monitoring and intermediate-range isobutane reference audits for leak detection.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High ±2% Analytical Accuracy.
- Certified Compliance: Non-Flammable UN1956 Certification.
- Data Logging: 48 Month Non-Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
RKI Instruments Isobutane 10% LEL IR-Grade N2-Bal 34L 722-103-10 delivers a secondary standard PRT probe for International Standards in oxygen-free environments and low-range isobutane infrared (IR) sensor audits.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High ±2% Analytical Accuracy.
- Certified Compliance: Inert Background Nitrogen Balance Standard.
- Data Logging: 48 Month Non-Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
RKI Instruments Isobutane 30% LEL IR-Grade N2-Bal 34L 722-103-30 acts as a secondary standard PRT probe for North American Standards in infrared (IR) detectors and mid-range isobutane calibration audits for anaerobic environments.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High ±2% Analytical Accuracy.
- Certified Compliance: Nitrogen Balance IR-Grade Standard.
- Data Logging: 48 Month Non-Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
BW PhD6 3145280NY Network Yellow Pump - 54-53-A03145280NY combines high-visibility yellow overmolding with an integrated motorized pump and enhanced network support for centralized data integration in confined spaces.
- Sensor Configuration: 6-channel LEL O2 H2S CO dual specialized toxic slots
- Sampling Method: Integrated motorized pump for active sampling
- Data Connectivity: NY series enhanced network wireless data transfer support
- Housing: Signature yellow high visibility polycarbonate overmold
- Power Source: Rechargeable lithium-ion Li-ion battery pack
BW PhD6 A10145280NY Alkaline Pumped Yellow - 54-53-A10145280NY is a weatherproof, high-range toxic monitor featuring an IR data link for Fleet Manager II compatibility and continuous pumped sampling in the field.
- Sensor Configuration: 6-channel specialized for high-range toxic monitoring
- IP Rating: IP65 67 weatherproof
- Sampling Method: Integrated motorized pump
- Power Source: Disposable alkaline dry cell battery pack
- Data Interface: Infrared IR data link for Fleet Manager II
BW PhD6 185280NW Wireless Alkaline - 54-53-A01185280NW is a wireless-ready 6-channel monitor that enables remote system alerts for personal safety and industrial plant safety audits.
- Sensor Configuration: LEL O2 H2S CO custom toxic
- Wireless Ready: NW series transmitter for remote alerts
- Power Source: Disposable alkaline dry cell battery pack
- User Interface: One-button operation with menu calibration
- Safety Rating: Intrinsically safe for hazardous locations
BW PhD6 215080N Alkaline Standard - 54-53-A01215080N is a general-purpose 6-channel detector with internal datalogging and RFI/EMI shielding for long-duration field assignments.
- Sensor Configuration: Standard 4-gas mix 2 open slots
- Power Source: Disposable alkaline dry cell battery pack
- Data Storage: Internal event and interval datalogger
- Calibration: Field adjustable with auto-span feature
- Durability: RFI EMI shielded impact resistant housing
BW PhD6 215280N Alkaline Diffusion - 54-53-A01215280N offers reliable 6-channel monitoring of standard hazardous gases with an impact-resistant overmold for daily personal safety.
- Sensor Configuration: LEL O2 H2S CO toxic slots
- Detection Range: LEL 100% O2 30% H2S 200ppm
- Power Source: Disposable alkaline dry cell battery pack
- Sampling Method: Diffusion passive ambient safety monitoring
- Operating Temp: -20°C to +50°C temperature range
BW PhD6 2215080N Toxic Li-ion - 54-53-A02215080N offers high-range toxic monitoring with real-time STEL/TWA concentration displays for facilities with on-site charging capabilities.
- Sensor Configuration: 6-channel high range toxic sensor configuration
- Power Source: Rechargeable lithium-ion Li-ion battery pack
- Display: Graphic LCD real-time concentration STEL TWA
- Safety Rating: Class I Div 1 intrinsically safe
- Datalogging: Standard event and interval recording included
BW PhD6 3180921NW Wireless IR Pumped - 54-53-A03180921NW features an integrated IR sensor for reliable combustible detection in oxygen-deficient atmospheres, supported by a built-in wireless transmitter for remote telemetry.
- Sensor Configuration: 6-channel integrated IR sensor for combustibles
- Special Feature: IR sensor for detection in oxygen deficient atmospheres
- Wireless Support: NW series built-in wireless transmitter for remote telemetry
- Sampling Method: Integrated motorized pump for active sampling
- Power Source: Rechargeable lithium-ion Li-ion battery pack
BW PhD6 60950A Specialized 060 Alkaline - 54-53-A01060950A features RFI/EMI resistant housing and specialized 060-series slots for personal safety monitoring of unique hazards in laboratory settings.
- Sensor Configuration: 6-channel specialized 060-series electrochemical slots
- Power Source: Disposable alkaline dry cell battery pack
- Protection: RFI EMI resistant housing
- Self-Test: Diagnostic checks for sensors battery and circuit integrity
- Sampling Method: Diffusion passive ambient monitoring
BW PhD6 3145280N Pumped Li-ion - 54-53-A03145280N combines high-capacity rechargeable power with a 300 ml/min pump flow rate for industrial hygiene and confined space monitoring.
- Sensor Configuration: 6-channel standard 4-gas 2 custom slots
- Sampling Method: Integrated motorized pump for active sampling
- Pump Flow Rate: Approximately 300 ml per minute with low-flow alarm
- Display: Backlit alphanumeric showing all 6 channels simultaneously
- Power Source: Rechargeable lithium-ion Li-ion battery pack