RKI Instruments Methane T-Series Auto-Dock Alum 34L 724-001-T acts as a precision thermal calibration unit for North American Standards in automated docking and precision 50% LEL methane reference audits for T-Series LEL sensors.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High ±2% Analytical Accuracy.
- Certified Compliance: T-Series Automated Docking Standard.
- Data Logging: 48 Month Non-Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.
RKI Instruments TEOS Smart Gas Detector PoE/Ethernet GD-70DPLN-TEOS delivers a secondary standard PRT probe for International Standards in semiconductor manufacturing and specialized TEOS monitoring audits for smart PoE/Ethernet transmitters.
- Operating Range: Pyrolyzer-assisted Electrochemical/Semiconductor.
- Accuracy Standard: High Integrated Suction Pump Sampling.
- Certified Compliance: Smart Transmitter Safe Area Standard.
- Data Logging: 4-20 mA and Ethernet (PoE) Records.
- Process Connection: Sensor Life and Circuit Integrity Interface.
BW PhD6 60950N Alkaline Standard Diffusion - 54-53-A01060950N delivers intrinsically safe personal protection for specific toxic chemical risks in zones where rechargeable power is restricted.
- Sensor Configuration: 6-channel specialized 060-series toxic slots
- Power Source: Disposable alkaline dry cell battery pack
- Safety Rating: Class I Div 1 groups A B C D intrinsically safe
- Alarm System: 95dB audible vibrating visual LED bar
- Operating Temp: -20°C to +50°C temperature range
BW PhD6 3145280ND Pumped Datalogging - 54-53-A03145280ND offers enhanced digital datalogging and active sampling for high-frequency data auditing and professional confined space entry.
- Sensor Configuration: 6-channel standard 4-gas dual 145-series toxic
- Datalogging: ND series enhanced digital datalogging capability
- Sampling Method: Integrated motorized pump for active sampling
- Interface: Standard 3-button menu with IR communication
- Protection: IP65 dust tight and water jet resistant
BW PhD6 95080NW Wireless 095-Series - 54-53-A01095080NW utilizes stability-optimized modules and an integrated NW transmitter for real-time safety tracking of field personnel within an impact-resistant polycarbonate housing.
- Sensor Configuration: 6-channel 095-series stability optimized modules
- Wireless Support: NW series network wireless telemetry transmitter
- Housing Material: Impact resistant polycarbonate with anti-vibration overmold
- Display Units: User selectable ppm percentage LEL Vol
- Power Source: Disposable alkaline dry cell battery pack
BW PhD6 2035280NW Wireless Toxic - 54-53-A02035280NW features integrated wireless telemetry and RFI/EMI shielding for full-shift personal monitoring in complex and hazardous toxic environments.
- Sensor Configuration: LEL O2 H2S CO toxic slots
- Connectivity: Integrated NW series wireless telemetry transmitter
- Power Source: Rechargeable lithium-ion Li-ion battery pack
- Housing Material: Impact resistant polycarbonate RFI EMI shielding
- Safety Rating: Class I Div 1 intrinsically safe
BW PhD6 2065080NW Wireless Remote - 54-53-A02065080NW delivers rechargeable 6-channel gas detection with specialized toxic modules and an IP65/67 rating for remote system polling.
- Sensor Configuration: 6-channel specialized 065-series toxic modules
- Wireless Support: Integrated NW module for remote polling
- Power Source: Rechargeable lithium-ion Li-ion battery pack
- IP Rating: IP65 67 dust tight water resistant
- Operating Temp: -20°C to +50°C temperature range
BW PhD6 2195080NW Wireless Li-ion - 54-53-A02195080NW integrates an NW wireless module for real-time fleet data management and high-reliability personal monitoring in industrial plants.
- Sensor Configuration: 6-channel 195-series stability optimized modules
- Connectivity: Network wireless NW module fleet data
- Power Source: Rechargeable lithium-ion Li-ion battery pack
- Compliance: Certified US CAN and European standards
- Self-Test: Automatic diagnostic check sensors battery circuitry
BW PhD6 2195280NW Wireless Turnaround - 54-53-A02195280NW provides a standard network wireless transmitter and IR data link for seamless software compatibility during long-duration maintenance tasks.
- Sensor Configuration: LEL O2 H2S CO toxic slots
- Wireless Support: NW series standard network wireless transmitter
- Power Source: Rechargeable lithium-ion Li-ion battery pack
- Data Interface: IR data link Fleet Manager compatibility
- Protection: Impact resistant housing anti-vibration overmold
BW PhD6 A09195280N Alkaline Pumped 195-Ser - 54-53-A09195280N features an integrated motorized pump with a 300 ml/min flow rate and RFI/EMI shielding for active remote sampling in hazardous zones without charging access.
- Sensor Configuration: 6-channel LEL O2 H2S CO dual 195-series toxic
- Sampling Method: Integrated motorized pump for active sampling
- Pump Flow Rate: Approximately 300 ml per minute with low-flow stall alarm
- Power Source: Disposable alkaline dry cell battery pack
- Housing Material: Ruggedized polycarbonate with RFI EMI shielding
BW PhD6 A14205280N Li-ion Pumped 6-Gas - 54-53-A14205280N delivers active remote sampling for refinery operations using high-stability 205-Series sensors and rechargeable power for extended field use.
- Sensor Configuration: 6-Channel 205-Series high-stability sensors
- Detection Range: LEL, O2, H2S, CO + Dual 205 Toxic slots
- Sampling Method: Integrated Motorized Pump (Active sampling)
- Power Source: Rechargeable Lithium-ion (Li-ion) Battery Pack
- Housing Material: Ruggedized polycarbonate with RFI/EMI shielding
BW PhD6 A14215080N Li-ion Pumped - 54-53-A14215080N offers high-capacity pumped monitoring for large industrial facilities and water treatment, featuring an IP65 weatherproof rating and 95dB audible alarms.
- Sensor Configuration: 6-Channel 215-Series toxic gas modules
- Power Source: Rechargeable Lithium-ion (Li-ion) Battery Pack
- Sampling Method: Integrated Motorized Pump
- IP Rating: IP65 (Dust tight and water jet resistant)
- Compliance: Certified to US/CAN (UL/CSA) and European (ATEX) standards
BW PhD6 A14215280N Li-ion Pumped 6-Gas - 54-53-A14215280N is a high-range remote sampling solution for hazmat response and industrial hygiene auditing, featuring built-in pump diagnostics and a standard IR data port.
- Sensor Configuration: 6-Channel; Standard 4-Gas + Dual 215-Series slots
- Sampling Method: Integrated Motorized Pump
- Flow Control: Built-in low-flow alarm and pump diagnostic sensor
- Power Source: Rechargeable Lithium-ion (Li-ion) Battery Pack
- Operating Temp: -20°C to +50°C (-4°F to 122°F)
BW PhD6 8000N7 N7 Stability Optimized - 54-53-A01028000N7 is optimized for long-term sensor stability and reduced drift, making it ideal for unique toxic gas exposures in mining or heavy manufacturing.
- Sensor Configuration: 6-channel specialized 028-series N7 toxic configuration
- N7 Series Feature: Optimized for long term sensor stability and reduced drift
- Power Source: Disposable alkaline dry cell battery pack
- Protection: RFI EMI shielded vibration dampening housing
- Self-Test: Automatic start up diagnostic check
BW PhD6 35280ND Alkaline Datalogging - 54-53-A01035280ND features enhanced internal memory for high-frequency logs and Fleet Manager II compatibility for extended data collection in hazardous areas.
- Sensor Configuration: 6-channel LEL O2 H2S CO dual 035-series toxic
- Datalogging: ND series enhanced internal memory high frequency logs
- Power Source: Disposable alkaline dry cell battery pack
- Interface: IR data link Fleet Manager II compatibility
- Display Units: User selectable ppm percentage LEL Vol
BW PhD6 235280ND Datalogging Alkaline - 54-53-A01235280ND offers high-frequency data recording and enhanced digital logging in a ruggedized polycarbonate housing for detailed industrial audits.
- Sensor Configuration: 6-channel 235-series specialized stability modules
- Datalogging: ND series enhanced digital event logging
- Power Source: Disposable alkaline dry cell battery pack
- Housing Material: Ruggedized polycarbonate with anti-vibration overmold
- Alarm System: 95dB audible vibrating visual LED bar
BW PhD6 3145280AW Adv. Wireless Pumped - 54-53-A03145280AW features advanced wireless telemetry and an integrated motorized pump for active remote sampling by hazmat and confined space teams.
- Sensor Configuration: LEL O2 H2S CO dual 145-series toxic
- Sampling Method: Integrated motorized pump for active sampling
- Connectivity: AW series advanced wireless telemetry transmitter
- Pump Flow: Low-flow alarm sensor with diagnostic stall detection
- IP Rating: IP65 dust tight and water jet resistant
BW PhD6 2095280ND Datalogging Li-ion - 54-53-A02095280ND features enhanced internal memory for detailed interval logging and a rechargeable battery for full-shift personal monitoring.
- Sensor Configuration: 6-channel stability optimized 095-series modules
- Data Management: ND series enhanced internal logging memory
- Power Source: Rechargeable lithium-ion Li-ion battery pack
- Battery Life: 24 hours of continuous operation
- Operating Temp: -20°C to +50°C temperature range
BW PhD6 2195280ND Datalogging Li-ion - 54-53-A02195280ND features high-capacity digital datalogging and stability-enhanced toxic modules for rigorous data tracking during plant turnarounds.
- Sensor Configuration: 6-channel 195-series stability enhanced modules
- Datalogging: ND series high capacity digital datalogging
- Power Source: Rechargeable lithium-ion Li-ion battery pack
- Self-Test: Automatic diagnostic check sensors battery circuitry
- Industrial Application: Advanced personal detection for plant turnarounds
RKI Instruments 4-Gas Mix IR-Optimized Alum 34L 72-5201RK-IR acts as a secondary standard PRT probe for North American Standards in infrared combustible gas sensor calibration and IR LEL response audits.
- Operating Range: 34 Liters High Pressure Aluminum.
- Accuracy Standard: High Infrared Optimized Response Precision.
- Certified Compliance: NIST Traceable Reference Standard.
- Data Logging: 24 Month Reactive Stability Records.
- Process Connection: C-10 5/8-18 UNF Valve Interface.