FIRST ORDER SHIPS FREE - No Minimum Purchase Required.

Until the end of the sale:
00
days
00
hours
00
minutes
00
sec.

Bacharach 0024-8401 Leakator 10 Refrigerant Leak Detector

SKU:

0024-8401

Bacharach 0024-8401 Optimize commercial environmental compliance audits with this industrial combustion analyzer featuring specialized sensors to execute simultaneous multiparameter industrial gas testing routines.

  • Tracks seven critical stack gases simultaneously including oxygen.
  • Maintains high five percent accuracy reading profiles.
  • Features heavy-duty transport suitcase hardware protection systems.
  • Utilizes efficient field-replaceable measurement gas sensor modules.
  • Includes dedicated sample conditioners and spare filtration kits.
$6,185.00

In Stock

Add to wishlist
Compare
SKU: 0024-8401 Category: Brand:
Wholesale Price
Request for Quotations

Description

The Bacharach 0024-8401 functions as a certified multi-gas combustion analyzer layout engineered to deliver stable reference points across heavy commercial boiler emissions networks. This integrated instrument package consolidates field-replaceable sensor matrices into a single heavy-duty diagnostic casing, functioning as an independent environmental testing station. Procurement specialists implement this universal setup to audit greenhouse gas footprints, completely removing the requirement to route multiple individual handheld gas monitors into active industrial boiler rooms.

This device handles active telemetry tracking loops using electrochemical arrays capable of tracking the simultaneous measurement of up to 7 gases including O2, CO, NO, NO2, and SO2. The underlying sensory layout achieves tight operational accuracy margins locked at ±0.3% Vol for O2 and ±5% of reading for CO, NOx, and SO2 parameters. This rugged suitcase design interfaces directly with a large backlit display, allowing field maintenance groups to monitor raw fuel combustion efficiency curves without encountering diagnostic reading drift across extended automated validation shifts.

Key Features of Bacharach 0024-8401

  • 7 Gas Simultaneous Measurement: Tracks critical factory emissions markers like sulfur dioxide and nitrogen oxides concurrently on a single screen.
  • ±0.3% Vol O2 Accuracy: Supplies tight validation tolerances required to align commercial burner fuel-to-air ratios with local environmental rules.
  • Field Replaceable Sensors: Accelerates automated on-site hardware maintenance by allowing technicians to swap sensory cells without factory assistance.
  • Rugged Suitcase Enclosure: Guards internal digital microprocessor circuits from impact forces, soot, and drop damage during active fieldwork.
  • Sample Conditioner Subsystem: Stabilizes erratic exhaust gas vapors before measurement to protect internal electronic sensors from moisture distortion.
  • Large Backlit LCD Display: Highlights diagnostic trends and multi-parameter gas curves clearly under dark facility industrial baselines.
  • 5-Gas Factory Standard Matrix: Combines oxygen, carbon monoxide, nitric oxide, nitrogen dioxide, and sulfur dioxide cells inside one casing.
  • Three Spare Filter Replacements: Secures continuous plant field testing capability by providing immediate infrastructure parts to trap exhaust particulates.

Instrument Configuration

The technical framework coordinates an automatic sample drawing pump with localized electrochemical sensor manifolds and an integrated moisture conditioning loop. This hardware layout interfaces live emissions data straight to internal memory banks, using a standard wall adapter power supply charging module to maintain continuous field deployment ready loops without system interruptions.

Industrial Applications

This automated bench instrument addresses the demanding tracking requirements of commercial glass factories, municipal power generation stations, and petrochemical processing facilities. Plant technical crews deploy the station to execute precision mass loop calibration procedures, checking industrial stack burners and heavy-duty HVAC boiler relays directly on site.

Warranty, CE Certificate and NIST Traceable Documentation

Produced by Bacharach, this commercial instrument features full 1-year manufacturer warranty coverage protecting both internal electrochemical sensors and the mainframe housing. The comprehensive kit arrives with printer paper rolls, line filters, and full operator diagnostic manuals, ensuring all compiled technical metadata satisfies strict commercial facility auditing frameworks.

BrandBacharach
MPN0024-8401
Model SKUBacharach ECA 450 Combustion Analyzer w/ NO, NO2, & SO2 Sensors
MeasurementSimultaneous measurement of up to 7 gases including O2, CO, NO, NO2, and SO2
AccuracyO2: ±0.3% Vol; CO: ±5% of reading; NOx/SO2: ±5% of reading
MaterialRugged suitcase design with large backlit display; field-replaceable sensors
Warranty1-Year Manufacturer Warranty (on sensors and mainframe)
Each Unit IncludesECA 450 Analyzer, Sample Conditioner, 3x Spare Filters, Printer Paper, Wall Adapter, and User Manual

Reviews

There are no reviews yet.

Be the first to review “Bacharach 0024-8401 Leakator 10 Refrigerant Leak Detector”

You may also like…

Shopping Cart

No products in the cart.

Free Shipping on All Orders Over $1,000

Log in

You dont have an account yet? Register Now

Type the product you want to search for and press enter.