FIRST ORDER SHIPS FREE - No Minimum Purchase Required.
Fluke P3022 Pneumatic Hand Pump (mBar P) – Pressure Only
Fluke P3022-MBAR-P Generating a manual pressure range from 15 to 1,000 mbar, this self-contained platform optimizes precision operations inside medical and aerospace metrology environments.
- 0.015% reading accuracy quantifies boundaries.
- External PressCal software tracks data.
- Integrated hardware drives pneumatic configurations.
- 120% FS limits system failures.
- Safety burst discs mitigate hazards.
In Stock
Description
Fluke P3022 Pneumatic Hand Pump (mBar P) – Pressure Only air-operated dual piston-cylinder unit resolves precision mbar-range verification errors inside medical and aerospace laboratories by leveraging a high-sensitivity pneumatic reference to deliver precise pressure ranges up to 1,000 mbar. Metrology engineers certifying master standard instruments or high-capacity pipeline sensors apply this primary standard platform to replace uncertain dial readings with exact physical laws of mass over area. The manual pneumatic hand control mechanism provides continuous fine fluid compression control, eliminating the erratic pressure stepping artifacts common in motorized or electronic laboratory validation systems.
A premium matched ceramic piston-cylinder assembly ensures exceptional wear resilience, holding highly repeatable cross-sectional area geometries under continuous pressure stroke validation stress. The structural framework includes thermal stability characterization for the effective area, compensating naturally for standard temperature swings to maintain an elite 0.015% of reading accuracy class. Standard gravity calibration parameters setup eliminates data processing distortions caused by software approximations, while safety burst discs guard internal lines from catastrophic mass-loading failures at 120% full scale.
Key Features of Fluke P3022 Pneumatic Hand Pump (mBar P) – Pressure Only
- 15 to 1,000 mbar operational span: Sourcing paths optimized for low-pressure gas pipelines, industrial draft loops, and specialized vacuum process indicators.
- Built-in vacuum and pressure pump: Eliminates reliance on external air compressors or heavy gas cylinders to maximize on-site field mobility.
- Frictionless ceramic piston-cylinder set: Reduces internal mechanical drag and friction profiles to secure excellent repeatability across weight loading cycles.
- 0.015% of reading accuracy class: Delivers elite metrological reference thresholds that adjust dynamically to active values rather than full-scale limits.
- Thermal stability characterized for Ae: Adjusts for room temperature variations using characterized area tracking metrics to prevent measurement drift.
- Standard gravity calibration baseline: Engineered natively at 9.80665 m/s² out of the box to guarantee exact, traceable mass-to-pressure force conversions.
- PressCal software data compatibility: Syncs with remote asset databases through manual references to export clean, error-free electronic calibration logs.
- 1/4″ NPT female process links: Connects with global industrial test fittings directly to speed up high-pressure connection workflows.
- Overpressure flow limit protection: Blocks extreme pneumatic lines mechanically at 120% full scale to isolate master reference standards from destructive velocity surges.
- ANSI Z540-1 quality compliance tracking: Furnishes certified out-of-the-box tracking parameters required to pass severe governmental quality control audits.
Precision Mbar-Range Pneumatic Standard for Medical and Aerospace Metrology
Designed for precision mbar-range pneumatic standard medical and aerospace metrology applications, this deadweight instrument optimizes laboratory calibration cycles through autonomous physical force tracking. The inclusion of a 1-year manufacturer warranty duration acts as direct validation, verifying that the precise wetted materials and internal check valves handle continuous mechanical strain. Operations teams maximize plant safety metrics during extensive turnaround schedules, keeping critical pipeline components closely aligned with strict international engineering guidelines.
Fluke P3022-MBAR-P Air Operated Dual PCU w/ Pump Technical Specs
| Brand | Fluke Calibration |
| Model SKU | P3022-MBAR-P |
| Country of Origin | United States |
| Specific Operating Range | 15 to 1,000 mbar (Vacuum to 1,000 mbar) |
| Accuracy Class | 0.015% of Reading (Signal Integrity Focused) |
| Piston-Cylinder / Sensor Material | Matched Ceramic Piston-Cylinder Assembly |
| Temperature Compensation | Thermal Stability Characterized for Ae |
| Gravity Correction | Standard Gravity Calibration (9.80665 m/s²) |
| Data Logging Capacity | External Data Logging Integration via PressCal |
| Interface & Port Type | 1/4" NPT Female (Built-in Vacuum/Pressure Pump) |
| Power & Battery Life | Manual Pneumatic Hand Control |
| Safety & Protection | Safety Burst Discs / Overpressure protection at 120% FS |
| Compliance | NIST Traceable, ISO/IEC 17025, ANSI Z540-1 |
| Warranty | 1 Year Manufacturer Warranty |
| Industrial Application | Precision mbar-range pneumatic standard for medical and aerospace metrology. |
You must be logged in to post a review.








Reviews
There are no reviews yet.