FIRST ORDER SHIPS FREE - No Minimum Purchase Required.

Until the end of the sale:
00
days
00
hours
00
minutes
00
sec.

Tektronix THDP0200 – 200 MHz 1.5kV High Voltage Diff Probe

SKU:

THDP0200

Tektronix THDP0200 Capture 200 MHz floating signals through 1 differential analog channel, with ±1500 V common-mode range and >80 dB rejection at 50 Hz for motor drive and UPS validation.

  • 200 MHz bandwidth resolves switching edges.
  • 1500 V common mode tolerates offsets.
  • 80 dB CMRR suppresses mains pickup.
  • 13 ns delay eases channel alignment.
  • 1 Year calibration maintains traceability.
$1,572.00

In Stock

Add to wishlist
Compare
SKU: THDP0200 Category: Brand:
Wholesale Price
Request for Quotations

Description

Tektronix THDP0200 is a 200 MHz high-voltage differential probe designed for safer, floating measurement scenarios where you need ≤ 1.8 ns rise time and ±1500 V (DC + pk AC) input sensitivity. With CMRR > 80 dB at 50 Hz and a listed ~13 ns propagation delay, it targets high common-mode rejection and repeatable timing when comparing differential waveforms in power systems.

THDP0200 supports TekVPI™ interface integration and direct connect to Tektronix MSO/DPO series instruments, so your capture triggering and timing alignment depend on the supported scope-probe chain. For analysis, the specs list power electronic switching analysis in the protocol/decoding section and high-voltage harmonic distortion analysis for spectral evaluation. This combination helps you inspect both switching behavior and distortion content after acquisition; if you’re comparing probe types, browse high voltage harmonic probes.

Key Features & Benefits of Tektronix THDP0200

  • 200 MHz bandwidth and ≤ 1.8 ns rise time support faster high-voltage transient capture.
  • ±1500 V (DC + pk AC) input sensitivity targets floating differential power measurements.
  • CMRR > 80 dB at 50 Hz supports stronger rejection of shared noise components.
  • ~13 ns propagation delay helps align timing during multi-channel comparisons.
  • High-voltage harmonic distortion analysis supports frequency-domain distortion checks.

Why Buy Tektronix THDP0200

Buy THDP0200 when your application needs more bandwidth than a 100 MHz high-voltage differential probe and you’re performing power electronic switching and distortion checks. The specs combine 200 MHz bandwidth with ≤ 1.8 ns rise time for fast transient visibility, plus ±1500 V (DC + pk AC) input sensitivity for high-voltage differential waveform coverage. The listed CMRR > 80 dB at 50 Hz improves measurement stability against common-mode interference, while the ~13 ns propagation delay supports consistent timing alignment. With TekVPI interface integration and high-voltage harmonic distortion spectral analysis specified, it supports both switching and frequency checks.

Switching Analysis And Warranty Support

Tektronix specifies THDP0200 for safe measurement of floating high-voltage signals in motor drives, UPS systems, and photovoltaic inverters, highlighting high common-mode rejection needs. Metrological compliance is stated as NIST traceable with UL61010-031 safety certified. Warranty support is listed as 1 Year with 12-Month calibration, and the country of origin is USA. Connectivity is specified as TekVPI™ probe interface with direct connect to Tektronix MSO/DPO series instruments. The specs also list an overrange indicator LED to support overload awareness during high-voltage captures.

Tektronix THDP0200 High Voltage Probe Specs

Brand & Full Model SKUTektronix THDP0200
Country of OriginUSA
Bandwidth & Rise Time200 MHz | ≤ 1.8 ns
Analog & Digital Channels1 Differential Analog Channel
Max Real-Time Sample RateHardware Dependent (Probe Only)
Waveform Update RateHardware Dependent (Probe Only)
Max Memory DepthHardware Dependent (Probe Only)
Vertical Resolution & High-Res ModeHardware Dependent (Probe Only)
Input Sensitivity & Noise Floor±1500 V (DC + pk AC) | CMRR: >80 dB at 50 Hz
Timebase Range & JitterPropagation Delay: ~13 ns
Hardware-Based TriggersTekVPI™ Interface Integration
Protocol Analysis & DecodingPower Electronic Switching Analysis
Spectral AnalysisHigh-Voltage Harmonic Distortion Analysis
Display & UI ArchitectureOverrange Indicator LED
Connectivity & InterfaceTekVPI™ Probe Interface
Multi-Instrument IntegrationDirect Connect to Tektronix MSO/DPO Series
Standard Warranty & Service Interval1 Year | 12-Month Calibration
Metrological ComplianceNIST Traceable, UL61010-031 Safety Certified
Industrial ApplicationSafe measurement of floating high-voltage signals in motor drives, UPS systems, and photovoltaic inverters requiring high common-mode rejection.

Reviews

There are no reviews yet.

Be the first to review “Tektronix THDP0200 – 200 MHz 1.5kV High Voltage Diff Probe”

You may also like…

Shopping Cart

No products in the cart.

Free Shipping on All Orders Over $1,000

Log in

You dont have an account yet? Register Now

Type the product you want to search for and press enter.